ECG100G single channel ECG is such a kind of electrocardiograph,which prints out the ECG waveforms with thermal printing system. Recording and displaying ECG waveforms in auto/manual mode;prompting the state of lead off and paper lack;switching the interface lauguages (Chinese/English).
Features
? 2.7" FSTN displayshows the working status and ECG waveform. Check the waveform before printing to save record paper.
?Output system:High-resolution thermal-array(32dots/mm),it needs not be adjusted.Recording frequency Response:Up to 150Hz.
?The device can record exact single ECG waveform and remark. The mark includes:lead sign,ensitivity,paper speed,filter state.
? Under automatic mode,just press the button once,it starts record procedure,which can enhance your work efficiency
?The language of operation interface include include(Chinese,English,French,Italian,Turkish,Espanol,Deutsch,Russia)
? The keyboard’s control is whole touch type,it’s convenient to operate.
? Classification:Class:I,CF defibrillator proof
? Power supply:AC/DC,rechargeable lithium battery inside.
? This instrument can record 160 pieces of ECG waveform and 4hours, standby for 10 hours continually under the best DC state
?The figure of whole device is elegancy and gliding
? According to defendence degree of deleterious fluid, this device is belong to common device.
? Digital signal processor for effective inhibition of AC,EMG and DFT,receive the better ECG waveform.
? According to the working mode class, this device belongs to continuous operation equipment.
Technical Specification:
Normal work environment
a. Environment temperature: +5?~+35?
b. Relative humidity: ≤80%
c. Atmospheric pressure: 86kPa~106kPa
Store and Transportation
a. Environment temperature: -10~55?
b. Relative humidity: ≤95%
c. Atmospheric pressure: 50kPa~106kPa
ECG instrument input
?Input way: Floating and defibrilation protection
?Lead: Standard 12 leads
?Patient leak current: <10μA
?Sampling rate:1000Hz
?A/D change:10 Bit
?Frequency response: 0.05Hz~150Hz(-3dB,+0.4dB)
?Time constant: Time constant>3.2s
?CMRR: >60dB, >100dB( With AC filter)
?Enduring polarization voltage:±500mV
?Noise level: ≤15μVp-p
?EMG interference filter: 35Hz(-3dB)
?AC filter:50Hz/60Hz(≥20dB)
?Sensitivity choice: 5,10,20mm/mV, error:±5%.Standard sensitivity is 10mm/mV±0.2mm/mV
?Recording way: Thermal printing system
?Auto-record: according the the record format and auto-mode to set, auto leads-changing, auto measurement.
?Manual record: according the record format to record, manual leads-changing.
?Specification of recording paper:50mm(W) × 20mm(L)High-speed thermal paper
?Paper speed: 25mm/s,50mm/s,error:±5%
?Product safety type:Class I, type CF defibrillator proof
?Fuse Specification:2 pcs φ5*20mm AC time lag; T1.6AL250V
?Size:315mm(L)*215mm(W)*77mm(H)
?Net Weight:1.5kg
?Power supply: AC:100~240V,50/60 Hz
DC: 7.4V, 2000 mAh rechargeable lithium battery
Accessories:
ECG leads 1 set
Limb electrode clamp 1 set
Chest electrode 1 set
Power connection 1 piece
Recording paper 1 piece
Ground wire 1 set
User manual 1 piece
Certification
CE, CCC